Preliminary Steps:
1. Capture a System Status salvo.
- Expand the Ultrix node and navigate to Database > Salvos.

2. Back up the database and frame settings.
- Navigate to System Status > Transfer > Ultricore Database > Select database to backup > Browse > Apply.

- (Optional) Navigate to Ultriscape > Head Selection; screenshot the PiP/layout assignments for each Ultriscape head.

Upgrade Steps:
When ready to upgrade, navigate to System Status > Upload > Browse (select .bin file) > Finish > Wait for upgrade to complete. Do not reboot yet.
- If you have any HDX boards, upload the HDX file now.
- If you have any IP boards, upload the IP file now.
- If you have any IPX boards, upload the IPX file now.
- If you have any MODX boards, upload the MODX file now
- You may now upload the frame file.
Once all files have been successfully applied, power cycle the system using the associated UltriPower unit(s) or unplugging the AC cables from the power supplies if using brick style power supplies.
Note do NOT unplug the small DC cables between power supply and Ultrix.
Post upgrade steps:
As of version 5.1.1 protocol services have been introduced. By default these are all disabled. To re-enable follow the steps below.
1. Open System status
2. On the network under system services select Change
3. Enable the protocol that are used with Ultrix