UltrixCarbonite Software Upgrade Guide
Current release: 7.1.13
Preliminary Steps:
- Download the .ultx_carb upgrade file
- Save a switcher set onto USB (Help Page: To Store a Set)
Upgrade through DashBoard:
- Drag the .ultx_carb upgrade file into the upgrade page in DashBoard (Configuration>System>Upgrade)
- Confirm to begin the upgrade
NOTE: Please do not interact with the switcher for the duration of the upgrade
Upgrade through USB (No DashBoard):
NOTE: Before you start please ensure your USB is formatted as FAT32. ExFAT will not work.
- Put the .ultx_carb file onto the root of the USB, it should be the only thing on there
- Plug the USB into the port on the switcher card
- On the panel navigate to Menu->Reset->Next->Next->Next->Run upgrade from USB
- Scroll to find the upgrade file
- Run the upgrade
NOTE: Please do not interact with the switcher for the duration of the upgrade
If this process should fail, follow the recovery upgrade instructions below:
NOTE: Before you start please ensure your USB is formatted as FAT32. ExFAT will not work.
- Move the .ultx_carb file onto the root of the USB, it should be the only thing on there
- Plug the USB into the port on the switcher card
- Ensure that DIP switch 4 is ON (Down). DIP switches are located on the Carbonite blade next to the USB port.
- Power Cycle the Carbonite
- Option 1 - Power down the Ultrix frame and Carbonite blade together, then power back on after 10 seconds.
- Option 2 - Turn on DIP switch 3, and press the recessed micro switch in between the DIP switches and the USB port.
- Once the upgrade is complete and the switcher is back up, make sure to turn off DIP switch 4 or it will try to upgrade again on next reboot.
NOTE: Shortly after the Carbonite boots up the UPGD light on the SDPE blade will come on, this indicates it is upgrading
NOTE: Please do not interact with the switcher for the duration of the upgrade